DSpace@MSGSÜ digitally stores academic resources such as books, articles, dissertations, bulletins, reports, research data published directly or indirectly by Mimar Sinan Fine Arts University in international standarts, helps track the academic performance of the university, provides long term preservation for resources and makes publications available to Open Access in accordance with their copyright to increase the effect of publications.

Search MSGSÜ
Advanced Search

Show simple item record

dc.contributor.authorDemirkıran, Erdem Kazım
dc.contributor.authorGür, N. Volkan
dc.contributor.authorÖkten, Mehmet Selim
dc.date.accessioned2022-06-08T18:31:08Z
dc.date.available2022-06-08T18:31:08Z
dc.date.issued2021
dc.identifier.issn2458-973X
dc.identifier.urihttps://doi.org/10.29187/jscmt.2021.62
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TkRrNU1qa3lNZz09
dc.identifier.urihttps://hdl.handle.net/20.500.14124/17
dc.description.abstractWood is preferred as building material in earthquake zones thanks to its light-weight. In countries with high seismic activity, wooden construction systems are required to be resistant to lateral and vertical loads. In traditional architecture, lateral load resistance is ensured with filled and unfilled walls which are strengthened with braces. In present day lateral load resistance is ensured with wooden shear walls formed by sheathings covered on the wall frame. Wooden shear walls may contain openings such as windows, doors and service channels. These types of openings reduce rigidity in wooden shear walls. The opening ratio, opening location, sheathing thickness and connection types have an impact on the lateral load bearing capacity of shear walls. This study investigates the use of two types of wooden shear walls with different-layout openings which were modelled with plywood sheathing material. For the purposes of this study, lateral load bearing capacities were calculated for both types of sheathing material of different thicknesses. The results are presented in tables by comparing the calculated capacity increase to the increase in weight.en_US
dc.language.isoengen_US
dc.relation.ispartofJournal of sustainable construction materials and technologies (Online)en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEffect of opening layout and sheathing on lateral load bearing capacity in wooden shear wallsen_US
dc.typearticleen_US
dc.department. . .en_US
dc.institutionauthor. . .
dc.identifier.doi10.29187/jscmt.2021.62
dc.identifier.volume6en_US
dc.identifier.issue2en_US
dc.identifier.startpage70en_US
dc.identifier.endpage80en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopus2-s2.0-85146756790
dc.identifier.trdizinidTkRrNU1qa3lNZz09en_US
dc.identifier.trdizinid499292
dc.identifier.scopusqualityQ4
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

  • TRDizin [1116]
    TR Index
  • Տcopus [1577]
    Scopus | Abstract and citation database

Show simple item record