Mimar Sinan Güzel Sanatlar Üniversitesi Açık Bilim, Sanat Arşivi

Açık Bilim, Sanat Arşivi, Mimar Sinan Güzel Sanatlar Üniversitesi tarafından doğrudan ve dolaylı olarak yayınlanan; kitap, makale, tez, bildiri, rapor gibi tüm akademik kaynakları uluslararası standartlarda dijital ortamda depolar, Üniversitenin akademik performansını izlemeye aracılık eder, kaynakları uzun süreli saklar ve yayınların etkisini artırmak için telif haklarına uygun olarak Açık Erişime sunar.

MSGSÜ'de Ara
Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorDemirkıran, Erdem Kazım
dc.contributor.authorGür, N. Volkan
dc.contributor.authorÖkten, Mehmet Selim
dc.date.accessioned2022-06-08T18:31:08Z
dc.date.available2022-06-08T18:31:08Z
dc.date.issued2021
dc.identifier.issn2458-973X
dc.identifier.urihttps://doi.org/10.29187/jscmt.2021.62
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TkRrNU1qa3lNZz09
dc.identifier.urihttps://hdl.handle.net/20.500.14124/17
dc.description.abstractWood is preferred as building material in earthquake zones thanks to its light-weight. In countries with high seismic activity, wooden construction systems are required to be resistant to lateral and vertical loads. In traditional architecture, lateral load resistance is ensured with filled and unfilled walls which are strengthened with braces. In present day lateral load resistance is ensured with wooden shear walls formed by sheathings covered on the wall frame. Wooden shear walls may contain openings such as windows, doors and service channels. These types of openings reduce rigidity in wooden shear walls. The opening ratio, opening location, sheathing thickness and connection types have an impact on the lateral load bearing capacity of shear walls. This study investigates the use of two types of wooden shear walls with different-layout openings which were modelled with plywood sheathing material. For the purposes of this study, lateral load bearing capacities were calculated for both types of sheathing material of different thicknesses. The results are presented in tables by comparing the calculated capacity increase to the increase in weight.en_US
dc.language.isoengen_US
dc.relation.ispartofJournal of sustainable construction materials and technologies (Online)en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEffect of opening layout and sheathing on lateral load bearing capacity in wooden shear wallsen_US
dc.typearticleen_US
dc.department. . .en_US
dc.institutionauthor. . .
dc.identifier.doi10.29187/jscmt.2021.62
dc.identifier.volume6en_US
dc.identifier.issue2en_US
dc.identifier.startpage70en_US
dc.identifier.endpage80en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinidTkRrNU1qa3lNZz09en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster